Direct intensive illumination of distant objects and codes.
Spot lights are supplied in different wavelengths
Optional optics with different profiles and light beam angles
Lighting intensity can be regulated by CM-01 Mini universal controller
Direct illumination of distant objects
Illumination of bar and 2D codes
Intense illumination of fast processes
Illumination of dull surfaces
Model Md
|
Voltage Span Un
|
Nominal Voltage Ujm
|
Nominal Current Ijm
|
Power consumption P
|
Trigger Voltage Utrig
|
Trigger Current Itrig
|
Analogue Dimming Uen
|
PWM Dimming Ien
|
Strobe Voltage Ustr
|
Strobe Current Istr
|
---|---|---|---|---|---|---|---|---|---|---|
SP-26W |
12-28 V |
24 V |
150 mA |
3,6 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
SP-26IR |
12-28 V |
24 V |
150 mA |
3,6 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
SP-26HIR |
12-28 V |
24 V |
150 mA |
3,6 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
SP-26HR |
12-28 V |
24 V |
150 mA |
3,6 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
SP-26R |
12-28 V |
24 V |
150 mA |
3,6 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
SP-26G |
12-28 V |
24 V |
150 mA |
3,6 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
SP-26B |
12-28 V |
24 V |
150 mA |
3,6 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
SP-26UV |
12-28 V |
24 V |
140 mA |
3,4 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
SP-26DB |
12-28 V |
24 V |
150 mA |
3,6 W |
≥ 10 - 24 V |
2,3 mA |
≥ 2,7 .. ≤ 10 V |
> 10 V .. ≤ 24 V |
3 - 24 V |
1,9 mA |
Model | A Length (mm) | B width (mm) | C Height (mm) | Weight (g) | |
---|---|---|---|---|---|
SP3-26 | 32 | 32 | 58 | 153 |
Terminal box output “OUT LIGHT T” – Light connection
Terminal +24 V: light positive pole
Terminal PWM: PWM signal
Terminal 0 V: light negative pole
Terminal box input "IN LIGHT T" – Power supply and control signal connection
Terminal +24 V: positive pole of 24 V DC Power Supply
Terminal 0 V: negative pole of 24 V DC Power Supply
Terminal TRIG: Trigger signal from camera, PLC, etc.
Manual and wiring instructions
Designed to drive any of 4 single Smart View lights and camera by one trigger signal.
Short circuit and output overload protection.